BECO WALLFORM


The Building Process


WALLFORM components have tongues on the top and grooves on the bottom, arranged so that they will interlock in parallel or at right angles in a modular grid of 62.5mm.

This means the designer can realise any plan layout to dimensions which are a multiple of 62.5mm. Smaller site dimensions may be cut exactly to size within the thickness of polystyrene once the concrete is cured.


Features of the WALLFORM System

  1. The tongues on the top and groves on the bottom of components are arranged to interlink and crosslink in a modular grid of 62.5mm.
  2. The tongues and grooves have a positive interlock so that the elements cannot be carried away by a gust of wind.
  3. The hollow core of the components is calculated to optimise economy of design and building processes.
  4. All faces have grooves 2.5mm deep and 17.5mm wide in a pattern repeated every 62.5mm to eliminate thermal bridging. These grooves have a dovetail profile to provide a mechanical key for the application of plaster.
  5. End pieces are inserted above and below the Wallblock cross-bridges to make a closure when forming corners, reveals and wall ends.
  6. The bridges are tapered at the top and bottom to avoid trapping air during concreting.
  7. The firewall endpiece is used to form the closure where this does not coincide with the bridge.

Further Features